☰ Navigation Tabs
Vigna radiata supercomplex I+III2 (full bridge)
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 8.062 f_angle_d 0.544 f_chiral_restr 0.042 f_plane_restr 0.004 f_bond_d 0.003
Sample Vigna radiata supercomplex I+III2 (full bridge)
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument LEICA EM GP Cryogen Name ETHANE Sample Vitrification Details 4 ul, 20 seconds pre-blot, blot 4 seconds
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 123451 Reported Resolution (Å) 3.2 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 60
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS GLACIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode OTHER Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION SerialEM CTF CORRECTION CTFFIND RECONSTRUCTION cryoSPARC MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE