☰ Navigation Tabs
EcMscK in an Open Conformation
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 7UW5
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 94414 Reported Resolution (Å) 3.48 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C7
Map-Model Fitting and Refinement Id 1 (7UW5) Refinement Space REAL Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON IV (4k x 4k) Electron Dose (electrons/Å**2) 46.16
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS GLACIOS Minimum Defocus (nm) 600 Maximum Defocus (nm) 2400 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 150000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version MODEL FITTING PHENIX RECONSTRUCTION cryoSPARC 3.1 MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE