Cryo-EM structure of AMPPNP-actin filaments
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 10.838 f_angle_d 0.952 f_chiral_restr 0.058 f_bond_d 0.009 f_plane_restr 0.007
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 310826 Reported Resolution (Å) 3.1 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 27.4 Angular Rotation -166.61
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol AB INITIO MODEL Refinement Target Correlation coefficient Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 45.71
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION SerialEM CTF CORRECTION Gctf RECONSTRUCTION RELION 3.0 MODEL REFINEMENT PHENIX 1.12_2829