5ARA
Bovine mitochondrial ATP synthase state 1a
ELECTRON MICROSCOPY
Sample |
---|
BOVINE MITOCHONDRIAL ATP SYNTHASE |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK III |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details | VITRIFICATION 1 -- CRYOGEN- ETHANE-PROPANE MIXTURE, HUMIDITY- 100, INSTRUMENT- FEI VITROBOT MARK III, METHOD- BLOT FOR 27 SECONDS BEFORE PLUNGING, |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 20104 |
Reported Resolution (Å) | 7.4 |
Resolution Method | |
Other Details | THE A SUBUNIT WAS MODELED USING EVOLUTIONARY CO-VARIANCE. THE N-TERMINAL TRANSMEMBRANE HELICES OF THE B SUBUNIT WERE MODELED BASED ON TRANSMEMBRANE HE ... |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (2WSS, 2XND, 2CLY) | ||||
Refinement Space | |||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | METHOD--FLEXIBLE FITTING |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 60.3 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2015-03-15 |
Temperature (Kelvin) | 80 |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1200 |
Maximum Defocus (nm) | 4100 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 18000 |
Calibrated Magnification | 30487 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | K2 SUMMIT DIRECT DETECTOR DEVICE OPERATED IN SUPER RESOLUTION MODE WITH A 1.64 ANGSTROM PHYSICAL PIXEL AND 0. 82 ANGSTROM SUPER RESOLUTION PIXEL. WITH NO SPECIMEN PRESENT, THE RATE OF EXPOSURE OF THE DETECTOR WAS 8 ELECTRONS PER PIXEL PER SECOND. EXPOSURE FRACTIONATED MOVIES OF 20.1 S WERE RECORDED AS STACKS OF 67 FRAMES, SO THAT SELECTED SPECIMEN AREAS WERE EXPOSED WITH A TOTAL OF 60.3 ELECTRONS PER SQUARE ANGSTROM. |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | MDFF | |
MODEL FITTING | UCSF Chimera | |
RECONSTRUCTION | FREALIGN | |
RECONSTRUCTION | RELION |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
EACH PARTICLE |