Skip to main content

 38RR | pdb_000038rr

Cryo-EM structure of Sr01-080, a denovo designed borneol dehydrogenase


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFold 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d12.85
f_angle_d0.5185
f_chiral_restr0.0428
f_plane_restr0.0088
f_bond_d0.0026
Sample
01_80
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles743562
Reported Resolution (Å)3.17
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsNon-uniform refinement in CryosPARC with D2 symmetry and refinement mask excluding neighboring particles in psuedo-filaments present in micrographs.
Refinement Type
Symmetry TypePOINT
Point SymmetryD2
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement Target
Overall B Value
Fitting Procedure
DetailsInitial fitting was done in chimeraX, and refined through sequential Real space refinement protocol in PHENIX and manual refinement with ISOLDE
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)52.88
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS GLACIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification100000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
MODEL REFINEMENTPHENIX2.0_5824
RECONSTRUCTIONcryoSPARC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION3922227Particles were picked using Blob Picker in CryoSPARC with min particle diameter 80 A, max particle diameter 120 A, and min separation distance 40 A. 5974094 picks were reduced with an Inspect Picks Job to 4494189, and an Extract Mics. (G) job reduced picks further to 3922227.