☰ Navigation Tabs
Kinesin-5-Tubulin Complex with AMPPNP
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 1MKJ experimental model PDB 1T5C experimental model PDB 2KIN
Sample MICROTUBULE-KLP61F COMPLEX WITH AMPPNP
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument Cryogen Name Sample Vitrification Details ETHANE
3D Reconstruction Reconstruction Method HELICAL Number of Particles Reported Resolution (Å) 9.4 Resolution Method Other Details THE KLP61F HOMOLOGY MODEL WAS GENERATED WITH MODELLER 9V1 AND THE FOLLOWING TEMPLATES - 1MKJ.PDB, 1T5C.PDB AND 2KIN.PDB Refinement Type Symmetry Type HELICAL
Map-Model Fitting and Refinement Id 1 (1MKJ, 1T5C, 2KIN) Refinement Space Refinement Protocol OTHER Refinement Target Overall B Value Fitting Procedure Details REFINEMENT PROTOCOL--HOMOLOGY (KLP61F), ELECTRON CRYSTALLOGRAPHY (TUBULIN)
Data Acquisition Detector Type KODAK SO-163 FILM Electron Dose (electrons/Å**2) 10
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TECNAI F20 Minimum Defocus (nm) 1080 Maximum Defocus (nm) 3940 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 50000 Calibrated Magnification 50000 Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version RECONSTRUCTION Ruby-Helix
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING, WIENER