Ts16 NMR solution structure
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 DQFCOSY 3.2 mM Ts16, 95% H2O, 5% D2O 95% H2O/5% D2O 3.5 ambient 298 2 TOCSY 3.2 mM Ts16, 95% H2O, 5% D2O 95% H2O/5% D2O 3.5 ambient 298 3 NOESY 3.2 mM Ts16, 95% H2O, 5% D2O 95% H2O/5% D2O 3.5 ambient 298 4 NOESY 3.2 mM Ts16, 95% H2O, 5% D2O 95% H2O/5% D2O 3.5 ambient 298
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Varian INOVA 500 2 Varian VNMRS 700
NMR Refinement Method Details Software simulated annealing Amber force field Amber
NMR Ensemble Information Conformer Selection Criteria 20 structures for lowest energy and no violations Conformers Calculated Total Number 200 Conformers Submitted Total Number 20 Representative Model 1 (no violations)
Computation: NMR Software # Classification Version Software Name Author 1 refinement Amber Case, Darden, Cheatham, III, Simmerling, Wang, Duke, Luo, and Kollm