9WBL | pdb_00009wbl

cryo-EM structure of RIBEYE B' filament


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6WKW 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d23.237
f_angle_d0.534
f_chiral_restr0.044
f_plane_restr0.005
f_bond_d0.003
Sample
RIBEYE B' domain
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles113042
Reported Resolution (Å)3.41
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise55.737
Angular Rotation-157.078
Map-Model Fitting and Refinement
Id1 (6WKW)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARCv3.3.1
IMAGE ACQUISITIONSerialEM3.7
CTF CORRECTIONCTFFIND4
MODEL FITTINGUCSF ChimeraX
INITIAL EULER ASSIGNMENTcryoSPARCv3.3.1
FINAL EULER ASSIGNMENTcryoSPARCv3.3.1
CLASSIFICATIONcryoSPARCv3.3.1
RECONSTRUCTIONcryoSPARCv3.3.1
MODEL REFINEMENTPHENIX1.18.2_3874
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE7756421