9ENQ

HSV-1 DNA polymerase-processivity factor complex in exonuclease state active site with 1-bp DNA mismatch


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7LUF 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it16.313
r_lrange_other16.301
r_dihedral_angle_6_deg15.189
r_dihedral_angle_3_deg10.948
r_dihedral_angle_other_2_deg10.189
r_scangle_it9.464
r_scangle_other9.463
r_dihedral_angle_2_deg8.495
r_mcangle_it6.904
r_mcangle_other6.903
RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it16.313
r_lrange_other16.301
r_dihedral_angle_6_deg15.189
r_dihedral_angle_3_deg10.948
r_dihedral_angle_other_2_deg10.189
r_scangle_it9.464
r_scangle_other9.463
r_dihedral_angle_2_deg8.495
r_mcangle_it6.904
r_mcangle_other6.903
r_dihedral_angle_1_deg6.22
r_scbond_it5.521
r_scbond_other5.517
r_mcbond_it4.195
r_mcbond_other4.195
r_angle_refined_deg1.419
r_angle_other_deg0.5
r_nbd_refined0.201
r_symmetry_nbd_other0.174
r_nbtor_refined0.168
r_xyhbond_nbd_refined0.132
r_metal_ion_refined0.102
r_chiral_restr0.075
r_symmetry_nbtor_other0.071
r_bond_refined_d0.006
r_gen_planes_refined0.005
r_gen_planes_other0.001
r_bond_other_d
Sample
HSV-1 DNA polymerase-processivity factor complex in exonuclease state with 1-bp DNA mismatch
Sample Components
DNA polymerase-processivity factor
DNA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles163943
Reported Resolution (Å)2.12
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7LUF)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)58
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)300
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.4
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot0.9.8.92
MODEL REFINEMENTCoot0.9.8.92
INITIAL EULER ASSIGNMENTcryoSPARC4.4
FINAL EULER ASSIGNMENTcryoSPARC4.4
RECONSTRUCTIONcryoSPARC4.4
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE