☰ Navigation Tabs
Cryo-EM structure of the BG505 SOSIPv2
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 6UDJ
Sample HIV-1 BG505 SOSIPv2 trimer
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details 3s blot, 0 blot force
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 1637484 Reported Resolution (Å) 2.9 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C3
Map-Model Fitting and Refinement Id 1 (6UDJ) Refinement Space REAL Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 60
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 3000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 105000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION Topaz IMAGE ACQUISITION SerialEM CTF CORRECTION cryoSPARC MODEL FITTING UCSF ChimeraX INITIAL EULER ASSIGNMENT cryoSPARC FINAL EULER ASSIGNMENT cryoSPARC RECONSTRUCTION cryoSPARC MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION