9VM8 | pdb_00009vm8

Structure of DOCK6 octamer


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d6.729
f_chiral_restr0.05
f_plane_restr0.006
f_bond_d0.005
f_angle_d
Sample
DOCK6 octamer
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles102384
Reported Resolution (Å)7.53
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)50.1
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification64000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcrYOLO
MODEL REFINEMENTPHENIX1.18.2_3874
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1793089