☰ Navigation Tabs
Cryo-EM structure of human Neurotensin Receptor 1 (hNTSR1)-Go complex in nucleotide-free C state
Refinement RMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 46.354 r_long_range_B_other 46.354 r_scangle_other 36.961 r_mcangle_it 28.215 r_mcangle_other 28.213 r_scbond_it 24.45 r_scbond_other 24.448 r_mcbond_it 20.038 r_mcbond_other 20.037 r_dihedral_angle_3_deg 14.425
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 46.354 r_long_range_B_other 46.354 r_scangle_other 36.961 r_mcangle_it 28.215 r_mcangle_other 28.213 r_scbond_it 24.45 r_scbond_other 24.448 r_mcbond_it 20.038 r_mcbond_other 20.037 r_dihedral_angle_3_deg 14.425 r_dihedral_angle_1_deg 6.187 r_dihedral_angle_2_deg 2.533 r_angle_refined_deg 1.582 r_angle_other_deg 0.647 r_chiral_restr 0.084 r_bond_refined_d 0.009 r_gen_planes_refined 0.009 r_gen_planes_other 0.004 r_bond_other_d 0.001 r_dihedral_angle_4_deg r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_scangle_it r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Sample JMV449-bound human Neurotensin Receptor 1 (hNTSR1)-Go complex in nucleotide-free C state with scFv16 Sample Components JMV449-bound human neurotensin receptor type 1 heterotrimeric Go protein scFv16
Specimen Preparation Sample Aggregation State PARTICLE
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 371296 Reported Resolution (Å) 3.37 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 1600 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE