9TF2 | pdb_00009tf2

Structure of echovirus 18, empty particle


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7B5F 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.1676
f_angle_d0.4671
f_chiral_restr0.0422
f_plane_restr0.0056
f_bond_d0.0018
Sample
Echovirus E18
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles3776
Reported Resolution (Å)2.86
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (6HBJ)
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement Targetcross-correlation
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)54.48
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)300
Maximum Defocus (nm)2400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcrYOLO1.9.3
CTF CORRECTIONCTFFIND4
MODEL FITTINGUCSF Chimera1.16
INITIAL EULER ASSIGNMENTRELION5.0.0
FINAL EULER ASSIGNMENTRELION5.0.0
RECONSTRUCTIONRELION5.0.0
MODEL REFINEMENTPHENIX1.21_5207
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION80069