Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Cryo-EM structure of H. neapolitanus CsoSCA in reducing conditions, hexamer
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s)
Type
Source
Accession Code
Details
in silico model
AlphaFold
AF-O85042-F1
Refinement
RMS Deviations
Key
Refinement Restraint Deviation
s_dihedral_angle_6_deg
13.5489
s_dihedral_angle_3_deg
12.2739
s_dihedral_angle_1_deg
6.9568
s_dihedral_angle_2_deg
3.4206
s_angle_nonh_deg
1.8675
s_hbond_nbd
0.2344
s_nbtor
0.2326
s_nbd
0.2222
s_symmetry_nbd
0.1348
s_metal_ion
0.1215
RMS Deviations
Key
Refinement Restraint Deviation
s_dihedral_angle_6_deg
13.5489
s_dihedral_angle_3_deg
12.2739
s_dihedral_angle_1_deg
6.9568
s_dihedral_angle_2_deg
3.4206
s_angle_nonh_deg
1.8675
s_hbond_nbd
0.2344
s_nbtor
0.2326
s_nbd
0.2222
s_symmetry_nbd
0.1348
s_metal_ion
0.1215
s_chiral_restr
0.0801
s_symmetry_hbond_nbd
0.0627
s_bond_nonh_d
0.0097
s_planes
0.0085
Sample
HnCsoSCA
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
4C, 100% relative humidity, delay time 0s, blot time 3s, blot force 0
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
545287
Reported Resolution (Å)
2.06
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
POINT
Point Symmetry
D3
Map-Model Fitting and Refinement
Id
1
Refinement Space
RECIPROCAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector Type
GATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)
64.757
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
TFS KRIOS
Minimum Defocus (nm)
600
Maximum Defocus (nm)
1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
130000
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
Topaz
0.2.5
IMAGE ACQUISITION
EPU
3.6.0
CTF CORRECTION
cryoSPARC
4.7
MODEL FITTING
UCSF ChimeraX
1.9
MODEL FITTING
ISOLDE
1.9
INITIAL EULER ASSIGNMENT
cryoSPARC
4.7
FINAL EULER ASSIGNMENT
cryoSPARC
4.7
CLASSIFICATION
cryoSPARC
4.7
RECONSTRUCTION
cryoSPARC
4.7
MODEL REFINEMENT
Servalcat
0.4.99
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
818243
Particles were picked with topaz, trained with a set of about 1000 particles picked manually from micrographs denoised by CryoSPARC. Topaz was trained and applied on raw micrographs.