9PVA | pdb_00009pva

295-330 S320F tau


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelOther 
Sample
295-330 S320F tau peptide fibril
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles46414
Reported Resolution (Å)3.7
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.768
Angular Rotation-2.38
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value69.01
Fitting Procedure
Details
Data Acquisition
Detector TypeTFS FALCON 4i (4k x 4k)
Electron Dose (electrons/Å**2)62
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION
MODEL FITTINGCoot0.981
RECONSTRUCTIONRELION5.0
MODEL REFINEMENTPHENIX1.20.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE