Skip to main content

 9OO5 | pdb_00009oo5

Cryo-EM structure of the dimeric YrvO cysteine desulfurase


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFold 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d3.247
f_angle_d0.374
f_chiral_restr0.038
f_bond_d0.002
f_plane_restr0.002
Sample
Dimer of YrvO cysteine desulfurase from Bacillus subtilis
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles93014
Reported Resolution (Å)3.5
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsThe atomic model was placed by fit in map tool available at Chimera followed by Dock in Map tool available in PHENIX. Then, several iterative cycles o ...The atomic model was placed by fit in map tool available at Chimera followed by Dock in Map tool available in PHENIX. Then, several iterative cycles of refinement using the phenix.real_space_refine in PHENIX with secondary structure restraints and manual adjustments in Coot provided the final cryo-EM model.
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
MODEL REFINEMENTPHENIX1.21.2_5419
RECONSTRUCTIONcryoSPARC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION44169522D templates for template-picking were obtained by a first blob picking (9,238,032 particles) followed by 2D classification. Eighty 2D -class averages were used for template picking with a particle diameter of 170 A. After template-picking, 4,416,952 particles were extracted using 440 pixels2 boxes, with a down-sampling factor of 4, and submitted to seven rounds of 2D classification to remove false picks, ice contamination, and classes with unclear features, resulting in 46 2D-class averages and a total of 312,209 particles.