Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
3-4 ul of sample double blotted for 3.5 seconds with -15 blot force on FEI Vitrobot mark IV.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
6252
Reported Resolution (Å)
3
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
POINT
Point Symmetry
I
Map-Model Fitting and Refinement
Id
1 (1HXS)
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
Cross-correlation coefficient
Overall B Value
Fitting Procedure
Details
Initial model was rigid body fitted using UCSF chimera and Coot. Global minimization and B-factor refinement
was performed in real space using pheni ...
Initial model was rigid body fitted using UCSF chimera and Coot. Global minimization and B-factor refinement
was performed in real space using phenix_real.space.refine.
Data Acquisition
Detector Type
FEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)
33.78
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
800
Maximum Defocus (nm)
2900
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
DARK FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
75000
Calibrated Magnification
129629
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Preliminary grid screening was performed on a Glacios 200 kV microscope.
EM Software
Task
Software Package
Version
PARTICLE SELECTION
crYOLO
CTF CORRECTION
RELION
3.0.7
MODEL FITTING
UCSF Chimera
1.16
MODEL FITTING
Coot
0.9.6
INITIAL EULER ASSIGNMENT
RELION
3.0.7
FINAL EULER ASSIGNMENT
RELION
3.0.7
CLASSIFICATION
RELION
3.0.7
RECONSTRUCTION
RELION
3.0.7
MODEL REFINEMENT
PHENIX
1.20.1_4487:
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
CTF correction performed in RELION v3.0.7 using CTFFIND4.
7185
Particle picking was performed using crYOLO after training the neural network on approx. 100 manually picked particles.