☰ Navigation Tabs
Cryo-EM structure of SARS-CoV-2 S-BQ.1 in complex with antibody O5C2
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 8.075 f_angle_d 0.634 f_chiral_restr 0.05 f_plane_restr 0.005 f_bond_d 0.003
Sample SARS-CoV-2 S-BQ.1 and antibody O5C2 complex Sample Components BQ.1 spike glycoprotein antibody O5C2, heavy chain antibody O5C2, light chain
Specimen Preparation Sample Aggregation State 3D ARRAY
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 1255741 Reported Resolution (Å) 3.6 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 2600 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE