8UY4

Acinetobacter baumannii Tse15 Rhs effector


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFold 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.292
f_angle_d0.47
f_chiral_restr0.039
f_bond_d0.003
f_plane_restr0.003
Sample
Recombinant Tse15
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles132696
Reported Resolution (Å)3.08
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsInitial fitting with done using UCSF Chimera using fit map.
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)500
Maximum Defocus (nm)1200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification150000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONGautomatch0.53
CTF CORRECTIONCTFFIND4.1.14
MODEL FITTINGUCSF Chimera1.15
MODEL REFINEMENTPHENIX1.19.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION455508