Oxiplasma meridianum archaellum
Refinement RMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 36.828 r_dihedral_angle_3_deg 13.611 r_dihedral_angle_4_deg 9.393 r_long_range_B_refined 5.209 r_dihedral_angle_1_deg 4.307 r_mcangle_it 1.98 r_scbond_it 1.538 r_angle_refined_deg 1.16 r_mcbond_it 1.063 r_chiral_restr 0.059
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 36.828 r_dihedral_angle_3_deg 13.611 r_dihedral_angle_4_deg 9.393 r_long_range_B_refined 5.209 r_dihedral_angle_1_deg 4.307 r_mcangle_it 1.98 r_scbond_it 1.538 r_angle_refined_deg 1.16 r_mcbond_it 1.063 r_chiral_restr 0.059 r_bond_refined_d 0.005 r_gen_planes_refined 0.002 r_bond_other_d r_angle_other_deg r_gen_planes_other r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_mcbond_other r_mcangle_other r_scbond_other r_scangle_it r_scangle_other r_long_range_B_other r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Sample Oxiplasma meridianum archaellum
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 1374113 Reported Resolution (Å) 2.54 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 5.641 Angular Rotation 107.922
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 51.45
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TALOS ARCTICA Minimum Defocus (nm) 800 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version MODEL REFINEMENT REFMAC 5.8.0267
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION