8Q92

P301S Tau Filaments from the Brains of PS19 Transgenic Mouse Line


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined18.529
r_long_range_B_other18.518
r_dihedral_angle_3_deg15.1
r_scangle_other13.868
r_mcangle_it8.071
r_mcangle_other8.068
r_scbond_it8.065
r_scbond_other8.053
r_dihedral_angle_1_deg6.955
r_mcbond_it5.077
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined18.529
r_long_range_B_other18.518
r_dihedral_angle_3_deg15.1
r_scangle_other13.868
r_mcangle_it8.071
r_mcangle_other8.068
r_scbond_it8.065
r_scbond_other8.053
r_dihedral_angle_1_deg6.955
r_mcbond_it5.077
r_mcbond_other5.067
r_dihedral_angle_2_deg2.065
r_angle_refined_deg1.196
r_angle_other_deg0.556
r_chiral_restr0.08
r_bond_refined_d0.006
r_gen_planes_refined0.006
r_gen_planes_other0.002
r_bond_other_d0.001
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
P301S Tau Protein Filament (PS19)
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles36951
Reported Resolution (Å)3.05
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.71
Angular Rotation-0.98
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)2400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification96000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION4.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1
RECONSTRUCTIONRELION4.1
MODEL REFINEMENTServalcat
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION