8OJ6

HSV-1 DNA polymerase-processivity factor complex in pre-translocation state


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7LUF 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it20.14
r_lrange_other20.132
r_dihedral_angle_6_deg17.059
r_dihedral_angle_3_deg13.813
r_scangle_it12.138
r_scangle_other12.137
r_mcangle_it9.357
r_mcangle_other9.356
r_dihedral_angle_2_deg9.247
r_dihedral_angle_1_deg8.093
RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it20.14
r_lrange_other20.132
r_dihedral_angle_6_deg17.059
r_dihedral_angle_3_deg13.813
r_scangle_it12.138
r_scangle_other12.137
r_mcangle_it9.357
r_mcangle_other9.356
r_dihedral_angle_2_deg9.247
r_dihedral_angle_1_deg8.093
r_scbond_it7.563
r_scbond_other7.563
r_mcbond_it6.274
r_mcbond_other6.274
r_angle_refined_deg1.575
r_angle_other_deg0.505
r_nbd_refined0.201
r_symmetry_nbd_other0.179
r_nbtor_refined0.179
r_xyhbond_nbd_refined0.132
r_chiral_restr0.094
r_symmetry_nbtor_other0.077
r_bond_refined_d0.007
r_gen_planes_refined0.007
r_gen_planes_other0.001
r_bond_other_d
Sample
HSV-1 DNA polymerase-processivity factor complex in pre-translocation state
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles58332
Reported Resolution (Å)2.41
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7LUF)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)58
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.3
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1
INITIAL EULER ASSIGNMENTcryoSPARC3.3
FINAL EULER ASSIGNMENTcryoSPARC4
CLASSIFICATIONcryoSPARC4
RECONSTRUCTIONcryoSPARC4
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE