8K4E

Cryo-EM structure of 30S ribosome with cleaved AP-mRNA bound complex-II


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7NAT 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d15.2427
f_angle_d0.9983
f_chiral_restr0.0518
f_plane_restr0.0086
f_bond_d0.0076
Sample
30S Ribosome with cleaved AP-mRNA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles42320
Reported Resolution (Å)3.4
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7NAT)
Refinement Space
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)41.53
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY