☰ Navigation Tabs
Human sodium-dependent vitamin C transporter 1 in an apo occluded state
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 8JEW
Refinement RMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 32.829 r_long_range_B_refined 23.658 r_long_range_B_other 23.658 r_dihedral_angle_4_deg 16.835 r_scangle_other 15.937 r_dihedral_angle_3_deg 14.287 r_mcangle_other 11.594 r_mcangle_it 11.586 r_scbond_it 10.437 r_scbond_other 10.435
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 32.829 r_long_range_B_refined 23.658 r_long_range_B_other 23.658 r_dihedral_angle_4_deg 16.835 r_scangle_other 15.937 r_dihedral_angle_3_deg 14.287 r_mcangle_other 11.594 r_mcangle_it 11.586 r_scbond_it 10.437 r_scbond_other 10.435 r_mcbond_it 8.178 r_mcbond_other 8.159 r_dihedral_angle_1_deg 3.866 r_angle_refined_deg 1.489 r_angle_other_deg 1.357 r_chiral_restr 0.08 r_gen_planes_refined 0.016 r_bond_refined_d 0.01 r_gen_planes_other 0.01 r_bond_other_d 0.002 r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_scangle_it r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Sample Human SVCT1 dimer in an apo occluded state
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 116307 Reported Resolution (Å) 2.85 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C2
Map-Model Fitting and Refinement Id 1 (8JEW) Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 50.9
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 1600 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 105000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 3.1.1 IMAGE ACQUISITION EPU 3.9.0 CTF CORRECTION RELION 3.1.1 MODEL FITTING Coot 0.9.6 INITIAL EULER ASSIGNMENT RELION 3.1.1 FINAL EULER ASSIGNMENT RELION 3.1.1 CLASSIFICATION RELION 3.1.1 RECONSTRUCTION RELION 3.1.1 MODEL REFINEMENT Servalcat 0.2.115
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 3699304