8GSB

SARS-COV-2 BA.1 Spike incomplex with VacBB-665


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7T9L 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d5.286
f_angle_d0.544
f_chiral_restr0.043
f_plane_restr0.005
f_bond_d0.002
Sample
Complex of SARS-COV-2 BA.1 Spike RBD and VacBB-665
Sample Components
SARS-COV-2 BA.1 Spike RBD
VacBB-665
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot for 5s, waiting for 2.5s, blot force 0
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles164748
Reported Resolution (Å)3.99
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (7T9L)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCorrelation coefficient
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONGctf1.18
MODEL FITTINGUCSF Chimera1.16
INITIAL EULER ASSIGNMENTcryoSPARC3.2
FINAL EULER ASSIGNMENTcryoSPARC3.2
CLASSIFICATIONcryoSPARC3.2
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTPHENIX1.20
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION4699769