8GAO
bacteriophage T4 stalled primosome with mutant gp41-E227Q
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 12.1 |
f_angle_d | 0.463 |
f_chiral_restr | 0.039 |
f_plane_restr | 0.003 |
f_bond_d | 0.002 |
Sample |
---|
complex of T4 primosome with mutant helicase gp41 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 272868 |
Reported Resolution (Å) | 4.1 |
Resolution Method | OTHER |
Other Details | lowest resolution in two combined focus refined maps |
Refinement Type | |
Symmetry Type | POINT |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 66 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1000 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | 3.8 |
CTF CORRECTION | CTFFIND | 4.1.10 |
MODEL FITTING | PHENIX | 1.20 |
MODEL REFINEMENT | PHENIX | 1.20 |
MODEL REFINEMENT | Coot | 0.9.6 |
INITIAL EULER ASSIGNMENT | cryoSPARC | 3.3.1 |
FINAL EULER ASSIGNMENT | RELION | 3.1 |
CLASSIFICATION | RELION | 3.1 |
RECONSTRUCTION | RELION | 3.1 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
NONE |