8E34

CryoEM structures of bAE1 captured in multiple states


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.372
f_angle_d0.584
f_chiral_restr0.042
f_plane_restr0.004
f_bond_d0.002
Sample
band 3 anion transport protein
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameNITROGEN
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles112436
Reported Resolution (Å)6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)52
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1400
Maximum Defocus (nm)3200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeOTHER
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification36764
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONLeginon3.2
CTF CORRECTIONCTFFIND4.1.8
MODEL FITTINGVMD1.9.3
MODEL REFINEMENTPHENIX1.19.2
INITIAL EULER ASSIGNMENTRELION2
FINAL EULER ASSIGNMENTRELION2
CLASSIFICATIONRELION2
RECONSTRUCTIONRELION2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONEstimated by CTFFIND4.2635578