7ZTD

Non-muscle F-actin decorated with non-muscle tropomyosin 3.2


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 5JLF 
experimental modelPDB 3J8A 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.849
f_angle_d1.042
f_chiral_restr0.06
f_plane_restr0.01
f_bond_d0.007
Sample
Non-muscle F-actin decorated with non-muscle tropomyosin 3.2
Sample Components
Beta actin (non-muscle)
Non-muscle tropomyosin 3.2
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles81431
Reported Resolution (Å)4.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise27.8
Angular Rotation-166.4
Map-Model Fitting and Refinement
Id1 (5JLF, 3J8A)
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)45
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGISOLDE
MODEL REFINEMENTPHENIX
RECONSTRUCTIONRELION
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION