7KFR

Adeno-Associated Virus (AAV-DJ) - cryo-EM structure at 1.56 Angstrom Resolution


ELECTRON MICROSCOPY
Sample
Adeno-associated virus
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsTwo 3uL aliquots applied to grid (manual blotting between), prior to automated 3 second blot before plunging.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles48209
Reported Resolution (Å)1.56
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsThese 48209 particles refined to approx. 2.2 A with I1 symmetry, and subsequent refinements of beam tilt and per-particle CTF brought the resolution t ...These 48209 particles refined to approx. 2.2 A with I1 symmetry, and subsequent refinements of beam tilt and per-particle CTF brought the resolution to 1.8 A. Further particle-polishing and subsequent re-refinement of CTF brought the resolution to 1.70 A and a final reconstruction using Ewald sphere correction ended at 1.56 A. The map used for modeling was sharpened using the volume whitening routine in cisTEM.
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (5UF6)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetLeast-squares residual
Overall B Value
Fitting Procedure
DetailsStand-alone RSRef was used for refinement of magnification, resolution, envelope correction and atomic B-factors. This was alternated with RSRef-embed ...Stand-alone RSRef was used for refinement of magnification, resolution, envelope correction and atomic B-factors. This was alternated with RSRef-embedded CNS was used for molecular dynamics optimization (1st round) and stereochemically-restrained all-atom least-squares optimization.
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)-800
Maximum Defocus (nm)-2600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification155000
Calibrated Magnification154400
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsComa-free alignment and objective astigmatism where corrected using Sherpa (Thermo Fisher, Inc.).
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONDoG Picker
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf
MODEL FITTINGCoot0.8.9.2
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
MODEL REFINEMENTRSRef0.5.8
MODEL REFINEMENTCNS1.3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY75316DoG (Difference of Gaussian) Picker was used for initial automated particle selection. Templates were then generated by 2D classification, followed by particle template selection in Relion 3.0.