7UN5
Structure of Type II Prion filaments from Gerstmann-Straussler-Scheinker disease
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 5.049 |
f_angle_d | 0.686 |
f_chiral_restr | 0.045 |
f_plane_restr | 0.004 |
f_bond_d | 0.003 |
Sample |
---|
Type II Prion protein filament from Gerstmann-Straussler-Scheinker disease |
Specimen Preparation | |
---|---|
Sample Aggregation State | FILAMENT |
Vitrification Instrument | GATAN CRYOPLUNGE 3 |
Cryogen Name | ETHANE |
Sample Vitrification Details | Plunge frozen in a BSL-2 hood |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 19341 |
Reported Resolution (Å) | 3.13 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 4.83 |
Angular Rotation | -0.94 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | AB INITIO MODEL | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 56.5 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | TFS KRIOS |
Minimum Defocus (nm) | 400 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 81000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | Leginon | |
RECONSTRUCTION | RELION | 3.1 |
MODEL REFINEMENT | PHENIX | |
MODEL REFINEMENT | Rosetta | |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |