☰ Navigation Tabs
Rabbit RyR1 with AMP-PCP and high Ca2+ embedded in nanodisc in closed-inactivated conformation class 2 (Dataset-A)
Sample Rabbit RyR1 with AMP-PCP and high Ca2+ in nanodisc
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details Sample was blotted for 1 second on both sides with Whatman hardened ashless filter paper with blot force 2.
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 159444 Reported Resolution (Å) 3.3 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 70
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 81000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 3.0 IMAGE ACQUISITION Latitude CTF CORRECTION Gctf 1.06 MODEL FITTING Coot 0.9.5 INITIAL EULER ASSIGNMENT RELION 3.0 FINAL EULER ASSIGNMENT RELION 3.0 CLASSIFICATION RELION 3.0 RECONSTRUCTION RELION 3.0 MODEL REFINEMENT PHENIX dev-1.20-4444-000
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 311258