7PG2
Low resolution Cryo-EM structure of full-length insulin receptor bound to 3 insulin, conf 1
ELECTRON MICROSCOPY
Sample |
---|
DDM solubilised full-length human insulin receptor with three insulins bound |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | LEICA EM GP |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blotted for 3s prior to plunging |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 27780 |
Reported Resolution (Å) | 6.7 |
Resolution Method | OTHER |
Other Details | Masked FSC calculated with GSFSC in cryoSPARC2 |
Refinement Type | |
Symmetry Type | POINT |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | |||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 60 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | NAMD | |
MODEL REFINEMENT | PHENIX | 1.19.2 |
RECONSTRUCTION | cryoSPARC | 2.15 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |