Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Initiated 70S ribosome in complex with 2A protein from encephalomyocarditis virus (EMCV)
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
Quantifoil R 2/2 400-mesh copper supports were coated with an additional ~ 60 angstrom layer of amorphous, evaporated carbon by flotation and thorough ...
Quantifoil R 2/2 400-mesh copper supports were coated with an additional ~ 60 angstrom layer of amorphous, evaporated carbon by flotation and thoroughly dried before use. Grids were made hydrophilic by glow-discharge in air for 30 s. Three microliters of crosslinking reaction was applied to grids which were then blotted for 4.5 s and vitrified by plunging into liquid ethane using a Vitrobot MK IV (FEI) at 277K, 100% relative humidity.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
120749
Reported Resolution (Å)
2.66
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
POINT
Point Symmetry
C1
Map-Model Fitting and Refinement
Id
1 (5MDZ)
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Correlation coefficient
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector Type
FEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)
54.4
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
1200
Maximum Defocus (nm)
3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
75000
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
RELION
3.1
IMAGE ACQUISITION
EPU
2.0
CTF CORRECTION
CTFFIND
4
CTF CORRECTION
RELION
3.1
MODEL FITTING
UCSF Chimera
1.15
INITIAL EULER ASSIGNMENT
RELION
3.1
FINAL EULER ASSIGNMENT
RELION
3.1
CLASSIFICATION
RELION
3.1
RECONSTRUCTION
RELION
3.1
MODEL REFINEMENT
PHENIX
1.91.1-4122
MODEL REFINEMENT
PHENIX
1.91.1-4122
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
The contrast transfer function (CTF) was estimated per-image using CtfFind4. All further phase+amplitude correction was performed internally in Relion. Per-particle CTF refinement was done after polishing
820475
Reference-free autopicking of particles was performed using the Laplacian-of-Gaussian function in Relion (200 - 250 angstrom diameter)