7ND0

lateral-open conformation of the wild-type BAM complex (BamABCDE) bound to a bactericidal Fab fragment


ELECTRON MICROSCOPY
Sample
wild-type beta-barrel assembly machinery (BAM) complex (BamABCDE) bound by a bactericidal Fab fragment
Sample Components
wild-type beta-barrel assembly machinery (BAM) complex (BamABCDE)
Light and heavy chains of bactericidal Fab fragment Fab1
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles131853
Reported Resolution (Å)5.2
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (5LJO, 5EKQ, 5LJO, 5LJO, 5LJO, 5LJO, 7BM5, 7BM5)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value183
Fitting Procedure
DetailsThe starting BAM model was created from 5LJO (lateral-open BAM-WT cryoEM structure) with BamA residues 687-700 replaced by those from 5EKQ (crystal st ...The starting BAM model was created from 5LJO (lateral-open BAM-WT cryoEM structure) with BamA residues 687-700 replaced by those from 5EKQ (crystal structure of BamACDE in a lateral-open conformation). This and 7BM5 (Fab1 crystal structure) were rigid fitted into the BAM-WT Fab1 complex electron density in UCSF Chimera. Molecular dynamics based flexible fitting was then set up in VMD and run in NAMD to fit the structures into the density. The resulting structure was finally real-space refined in phenix to generate the final model.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)GATAN K2 SUMMIT (4k x 4k)GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)74.959.860.9
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1750
Maximum Defocus (nm)3250
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf1.18
MODEL FITTINGUCSF Chimera
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTcryoSPARC2.2.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
RECONSTRUCTIONcryoSPARC2.2.0
MODEL REFINEMENTNAMD
MODEL REFINEMENTMDFF
MODEL REFINEMENTVMD
MODEL REFINEMENTPHENIX1.14
MODEL REFINEMENTCoot0.9
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION703997