7NCS

Lateral-open conformation of the lid-locked BAM complex (BamA E435C S665C, BamBDCE) bound by a bactericidal Fab fragment


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7NBX 
experimental modelPDB 7BM5 
Sample
lid-locked beta-barrel assembly machinery (BAM) complex (BamABCDE) bound by a bactericidal Fab fragment
Sample Components
lid-locked beta-barrel assembly machinery (BAM) complex (BamABCDE)
Light and heavy chains of bactericidal Fab fragment Fab1
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles61777
Reported Resolution (Å)7.1
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsHalf maps from non-uniform refinement in cryoSPARC were postprocessed in RELION 3.0 to generate the final map
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7NBX, 7NBX, 7NBX, 7NBX, 7NBX, 7BM5, 7BM5)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value183
Fitting Procedure
Details7NBX (lateral-open BAM-LL cryoEM structure) and 7BM5 (Fab1 crystal structure) were rigid fitted into the electron density in UCSF Chimera. One round ...7NBX (lateral-open BAM-LL cryoEM structure) and 7BM5 (Fab1 crystal structure) were rigid fitted into the electron density in UCSF Chimera. One round of molecular dynamics based flexible fitting was then set up in VMD and run in NAMD to fit the structures into the BAM-LL-Fab1 density. The resulting structure was finally real-space refined in phenix to generate the final model.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)49.1
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcrYOLO1.4.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf1.18
MODEL FITTINGUCSF Chimera
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTcryoSPARC2.2.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
RECONSTRUCTIONcryoSPARC2.2.0
MODEL REFINEMENTNAMD
MODEL REFINEMENTMDFF
MODEL REFINEMENTVMD
MODEL REFINEMENTPHENIX1.14
MODEL REFINEMENTCoot0.9
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION162844