7F8J

Cryo-EM structure of human pannexin-1 in a nanodisc


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d10.015
f_angle_d1.294
f_chiral_restr0.038
f_plane_restr0.003
f_bond_d0.002
Sample
heptamar of human pannexin-1 channel in a nanodisc
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA KF80
Cryogen NameETHANE
Sample Vitrification Detailsblot for 10 seconds at room temperature followed by plunge freezing. Because of manual blotting, humidity and temperature in a room is not controlled. ...blot for 10 seconds at room temperature followed by plunge freezing. Because of manual blotting, humidity and temperature in a room is not controlled.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles55718
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value146.5
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelJEOL CRYO ARM 300
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelJEOL
Nominal Magnification40000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONEMAN2
CTF CORRECTIONCTFFIND4
INITIAL EULER ASSIGNMENTRELION3.0
RECONSTRUCTIONRELION3.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY1533798