☰ Navigation Tabs
TRPC4 in complex with inhibitor GFB-9289
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 6G1K
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 22.0277 f_angle_d 0.7922 f_chiral_restr 0.046 f_bond_d 0.009 f_plane_restr 0.005
Sample TRPC4 in complex with inhibitor GFB-9289
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 65811 Reported Resolution (Å) 3.15 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C4
Map-Model Fitting and Refinement Id 1 (6G1K) Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Correlation coefficient Overall B Value 46.76 Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 65.45
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1600 Maximum Defocus (nm) 2800 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification Calibrated Magnification 55000 Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION EPU CTF CORRECTION CTFFIND 4.1.10 CTF CORRECTION RELION 3.0.4 MODEL FITTING Coot 0.8.8 FINAL EULER ASSIGNMENT RELION 3.0.4 CLASSIFICATION RELION 3.0.4 RECONSTRUCTION RELION 3.0.4 MODEL REFINEMENT PHENIX 1.18.2
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 434945