6R21

Cryo-EM structure of T7 bacteriophage fiberless tail complex


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6QWP 
experimental modelPDB 5MU4 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d11.986
f_angle_d1.157
f_chiral_restr0.065
f_bond_d0.008
f_plane_restr0.007
Sample
Bacteriophage tail complex
Sample Components
Portal protein
Adaptor protein
Nozzle protein
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles92382
Reported Resolution (Å)3.33
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC6
Map-Model Fitting and Refinement
Id1 (6QWP)2 (5MU4)3
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FITRIGID BODY FITAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)0.84
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONGautomatch
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTRELION
CLASSIFICATIONRELION
RECONSTRUCTIONRELION
IMAGE ACQUISITIONScipion
MODEL REFINEMENTREFMAC
MODEL REFINEMENTPHENIX
MODEL FITTINGCoot
MODEL REFINEMENTREFMAC
MODEL REFINEMENTPHENIX
MODEL FITTINGCoot
MODEL REFINEMENTREFMAC
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION