6YG8
Cryo-EM structure of a BcsB pentamer in the context of an assembled Bcs macrocomplex
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 5.15 |
f_angle_d | 0.553 |
f_chiral_restr | 0.047 |
f_bond_d | 0.004 |
f_plane_restr | 0.004 |
Sample |
---|
Co-expression of Bcs subunits R, Q, A, B, E, F and G lead to the purification of a membrane complex assembly |
Sample Components |
Homopentameric assembly of the BcsB protein |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 576455 |
Reported Resolution (Å) | 3 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 1.2 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 750 |
Maximum Defocus (nm) | 2750 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | v2 |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | Gctf | |
INITIAL EULER ASSIGNMENT | cryoSPARC | V2 |
FINAL EULER ASSIGNMENT | cryoSPARC | V2 |
CLASSIFICATION | cryoSPARC | V2 |
RECONSTRUCTION | cryoSPARC | v2 |
MODEL REFINEMENT | PHENIX | 1.16-3549-000 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | Gctf through the cryoSPARC v2 interface. |