☰ Navigation Tabs
Moevan: a designed granulopoietic protein by topological rescaffolding
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 3D HNCO 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 600 2 3D HNCO 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 313 Bruker AVANCE III 600 3 3D HNCA 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 600 4 3D HNCA 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 313 Bruker AVANCE III 600 5 3D HNCACB 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 600 6 3D HNCACB 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 313 Bruker AVANCE III 600 7 3D (H)CC(CO)NH 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 600 8 3D (H)CC(CO)NH 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 313 Bruker AVANCE III 600 9 3D CCH-TOCSY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 600 10 3D CCH-TOCSY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 313 Bruker AVANCE III 600 11 2D NOESY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 800 12 3D CNH-NOESY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 800 13 3D CNH-NOESY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 313 Bruker AVANCE III 800 14 3D 1H-13C NOESY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 800 16 3D 1H-15N NOESY 600 uM [U-99% 13C; U-99% 15N] Moevan, 50 mM PBS 90% H2O/10% D2O 125 mM 5.2 1 atm 298 Bruker AVANCE III 800
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE III 600 2 Bruker AVANCE III 800
NMR Refinement Method Details Software NOESY back-calculation models are selected from a pool of MD frames based on an R-factor expressing the match between back-calculated and experimental spectra CoMAND
NMR Ensemble Information Conformer Selection Criteria back calculated data agree with experimental NOESY spectrum Conformers Calculated Total Number 20000 Conformers Submitted Total Number 14 Representative Model 1 (medoid)
Computation: NMR Software # Classification Version Software Name Author 1 collection TopSpin Bruker Biospin 2 chemical shift assignment Sparky Goddard 3 structure calculation Rosetta Baker 4 refinement CoMAND in house