Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Complex consisting of actin-filament nucleator, Arp2/3 complex associated with nucleation promoting factor Dip1 and first four actin subunits from the pointed end of the nucleated actin-filament
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
HOMEMADE PLUNGER
Cryogen Name
ETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
110433
Reported Resolution (Å)
3.9
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
POINT
Point Symmetry
C1
Map-Model Fitting and Refinement
Id
1 (3DWL, 3J8I, 6D8C)
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector Type
FEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)
36.35
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TALOS ARCTICA
Minimum Defocus (nm)
-1000
Maximum Defocus (nm)
-1750
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
92000
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
200
Imaging Details
Data were collected by stage shifting to targeted exposure positions.
EM Software
Task
Software Package
Version
PARTICLE SELECTION
RELION
3.0.6
IMAGE ACQUISITION
EPU
2.1
CTF CORRECTION
Gctf
1.06
MODEL FITTING
NAMD
MODEL FITTING
Coot
MODEL FITTING
UCSF Chimera
FINAL EULER ASSIGNMENT
RELION
3.0.6
CLASSIFICATION
RELION
3.0.6
RECONSTRUCTION
RELION
3.0.6
MODEL REFINEMENT
PHENIX
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
Particles were CTF corrected during projection matching and back projection.
3500000
Particles were picked using Laplacian Gaussian auto-picking.