Cryo-EM structure of TypeII tau filaments extracted from the brains of individuals with Corticobasal degeneration


ELECTRON MICROSCOPY
Sample
Tau filaments extracted from the Frontal cortex of a patient with corticobasal degeneration.
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsBlot force: -12 ; Blot time: 4s
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles20752
Reported Resolution (Å)3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC2
Axial Rise4.786
Angular Rotation-0.61
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement TargetFourier shell correlation
Overall B Value25.75
Fitting Procedure
DetailsA stack of three consecutive monomers was refined to preserve nearest-neighbour interactions for the middle chain. Because most residues adopted cross ...A stack of three consecutive monomers was refined to preserve nearest-neighbour interactions for the middle chain. Because most residues adopted cross strand conformation, hydrogen-bond restraints were imposed to preserve a parallel, in-register hydrogen bonding pattern in earlier stages of Fourier-space refinements. Local symmetry restraints were imposed to keep all beta strand rungs identical. Side-chain clashes were detected using MOLPROBITY, and corrected by iterative cycles of real-space refinement in COOT and Fourier-space refinement in REFMAC and PHENIX. For each refined structure, separate model refinements were performed against a single half-map, and the resulting model was compared to the other half-map to confirm the absence of overfitting.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)1.346
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1700
Maximum Defocus (nm)2800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONEPU1.10.0.77REL
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot0.8.9.1
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
MODEL REFINEMENTREFMAC5.8.0256
MODEL REFINEMENTPHENIXdev-2919
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONAligned, non-dose-weighted micrographs were used to estimate the contrast transfer function (CTF) using CTFFIND4.1129812Manually picked