CryoEM Structure of Pyocin R2 - precontracted - trunk
Specimen Preparation Sample Aggregation State HELICAL ARRAY Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 15487 Reported Resolution (Å) 2.9 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C6 Axial Rise 39.46 Angular Rotation 18.3
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 QUANTUM (4k x 4k) Electron Dose (electrons/Å**2) 80
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 2160 Maximum Defocus (nm) 2160 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 130000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION Leginon 3.2 CTF CORRECTION RELION 1.4 FINAL EULER ASSIGNMENT RELION 1.4 RECONSTRUCTION RELION 1.4 MODEL REFINEMENT PHENIX 1.13
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 15684