SARS-CoV-2 RNA-dependent RNA polymerase in complex with cofactors
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK II
Cryogen Name
ETHANE
Sample Vitrification Details
blot for 3 seconds before plunging.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
110176
Reported Resolution (Å)
2.9
Resolution Method
FSC 0.143 CUT-OFF
Other Details
The particle set was used to perform homogeneous refinement, yielding a resolution of 3.1-angstrom. After local refinement, the final resolution reach ...
The particle set was used to perform homogeneous refinement, yielding a resolution of 3.1-angstrom. After local refinement, the final resolution reached 2.9-angstrom.
Refinement Type
Symmetry Type
POINT
Point Symmetry
C1
Map-Model Fitting and Refinement
Id
1 (6NUR, 6NUR, 6NUR, 6NUR)
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
correlation coefficient
Overall B Value
65
Fitting Procedure
Details
After the corresponding amino acids were replaced with
those from 2019-nCoV, the model was manually built in Coot with the guidance of the cryo-EM map ...
After the corresponding amino acids were replaced with
those from 2019-nCoV, the model was manually built in Coot with the guidance of the cryo-EM map, and in combination with real space refinement with Phenix.
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)
60
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
1000
Maximum Defocus (nm)
2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
165000
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Preliminary grid screening was performed manually.
EM Software
Task
Software Package
Version
IMAGE ACQUISITION
SerialEM
3-7-3
CTF CORRECTION
cryoSPARC
2.9.1
MODEL FITTING
UCSF Chimera
1.14
MODEL REFINEMENT
PHENIX
1.16
INITIAL EULER ASSIGNMENT
cryoSPARC
2.9.1
FINAL EULER ASSIGNMENT
cryoSPARC
2.9.1
CLASSIFICATION
cryoSPARC
2.9.1
RECONSTRUCTION
cryoSPARC
2.9.1
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
The CTF correction was done by patch CTF correction.
2334248
The particles were automatically selected using blob pickier (diameter range from 100 angstroms to 150 angstroms)