6IC3

AL amyloid fibril from a lambda 1 light chain


ELECTRON MICROSCOPY
Sample
Amyloid fibril of an antibody lambda 1 light chain
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentGATAN CRYOPLUNGE 3
Cryogen NameETHANE
Sample Vitrification Detailsblotted from the backside for 4 s before plunging
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles32677
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.81
Angular Rotation0.58
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement TargetREAL-SPACE (WEIGHTED MAP SUM AT ATOM CENTERS)
Overall B Value111.4
Fitting Procedure
DetailsRefinement strategy included global minimization and local grid search and ADP were refined. Secondary structure restraints and NCS were applied durin ...Refinement strategy included global minimization and local grid search and ADP were refined. Secondary structure restraints and NCS were applied during refinement.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)32
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONGctf1.06
MODEL FITTINGWarp8.0
MODEL FITTINGCoot0.8.9
INITIAL EULER ASSIGNMENTRELION2.1.0
CLASSIFICATIONRELION2.1.0
RECONSTRUCTIONRELION2.1.0
MODEL REFINEMENTPHENIX1.14.3260
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONCTF was estimated from the non-dose-weighted micrographs119395manual selection. Sigma contrast 3, lowpass filter 20 A