6I5A

Tobacco Mosaic Virus


ELECTRON MICROSCOPY
Sample
Tobacco mosaic virus
Specimen Preparation
Sample Aggregation StateHELICAL ARRAY
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsQuantifoil 400 mesh copper grids R 1.2/1.3 were used (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were glow discharged in air at a pressure of ...Quantifoil 400 mesh copper grids R 1.2/1.3 were used (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were glow discharged in air at a pressure of 2.2x10-2 Torr for 2 min at medium power with a Harrick Plasma cleaner (PDC-002). Subsequently, 3-4 ul of the sample was pipetted onto the glow discharged grids and plunge frozen in liquid Ethane with a Vitrobot IV (FEI). The sample chamber of the Vitrobot was maintained at 4C and 100% humidity. Wait time between sample application and blotting was 45 s, the drain time 0 s, the blot time 3 s and the blot force 0.
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles91927
Reported Resolution (Å)2.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise1.39615
Angular Rotation22.037
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value105
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)55
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONEPU
CTF CORRECTIONRELION
MODEL FITTINGWarp8.0
MODEL REFINEMENTWarp8.0
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION393692For TMV, some helices were picked manually with the helix picker implemented in relion 2.1. An initial 3D model of these segments was determined using the relion helix option with a cylinder as the starting reference. The aligned helical segments after 3D refinement were subjected to 2D classification without alignment. Three of the 2D class averages were selected as templates for automatic picking of the TMV segments in relion.