6I5A
Tobacco Mosaic Virus
ELECTRON MICROSCOPY
Sample |
---|
Tobacco mosaic virus |
Specimen Preparation | |
---|---|
Sample Aggregation State | HELICAL ARRAY |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Quantifoil 400 mesh copper grids R 1.2/1.3 were used (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were glow discharged in air at a pressure of ... |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 91927 |
Reported Resolution (Å) | 2.3 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 1.39615 |
Angular Rotation | 22.037 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | AB INITIO MODEL | ||||
Refinement Target | |||||
Overall B Value | 105 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON III (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 55 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1000 |
Maximum Defocus (nm) | 1800 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 75000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | RELION | 3.0 |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | RELION | |
MODEL FITTING | Warp | 8.0 |
MODEL REFINEMENT | Warp | 8.0 |
INITIAL EULER ASSIGNMENT | RELION | |
FINAL EULER ASSIGNMENT | RELION | 3.0 |
CLASSIFICATION | RELION | 3.0 |
RECONSTRUCTION | RELION | 3.0 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 393692 | For TMV, some helices were picked manually with the helix picker implemented in relion 2.1. An initial 3D model of these segments was determined using the relion helix option with a cylinder as the starting reference. The aligned helical segments after 3D refinement were subjected to 2D classification without alignment. Three of the 2D class averages were selected as templates for automatic picking of the TMV segments in relion. |