NMR Structural and biophysical functional analysis of intracellular loop 5 of the NHE1 isoform of the Na+/H+ exchanger.
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 1D Proton 5 mM peptide 90% H2O/10% D2O 440 mM 6 960 mbar 300 Varian VNMRS 600 2 2D NOESY 5 mM peptide 90% H2O/10% D2O 440 mM 6 960 mbar 300 Varian VNMRS 600 3 2D HSQC 5 mM peptide 90% H2O/10% D2O 440 mM 6 960 mbar 300 Varian VNMRS 600 4 2D TOCSY 5 mM peptide 90% H2O/10% D2O 440 mM 6 960 mbar 300 Varian VNMRS 600
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Varian VNMRS 600
NMR Refinement Method Details Software torsion angle dynamics automatic CYANA
NMR Ensemble Information Conformer Selection Criteria structures with the lowest energy Conformers Calculated Total Number 20 Conformers Submitted Total Number 20 Representative Model 1 (lowest energy)
Computation: NMR Software # Classification Version Software Name Author 1 collection VnmrJ 4.2 Agilent 5 processing NMRPipe 8.9 Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax 6 peak picking NMRView Johnson, One Moon Scientific 2 structure calculation CYANA 2.1 Guntert, Mumenthaler and Wuthrich