DnaB helicase - Lambda P helicase loader DNA replication complex
Sample Components
E coli DnaB helicase
Lambda P helicase loader
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
3uL of sample was adhered to a fresh plasma cleaned grid and allowed to adsorb for 30 seconds, blotted for 3 seconds with a blot force of 4 and plunge ...
3uL of sample was adhered to a fresh plasma cleaned grid and allowed to adsorb for 30 seconds, blotted for 3 seconds with a blot force of 4 and plunge frozen into liquid nitrogen-cooled ethane.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
90883
Reported Resolution (Å)
4.1
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Relion was used to independently refine half sets using 0.143 gold-standard to a resolution of 4.1A. A total of 90,883 particles went into this recons ...
Relion was used to independently refine half sets using 0.143 gold-standard to a resolution of 4.1A. A total of 90,883 particles went into this reconstruction.
Refinement Type
Symmetry Type
Map-Model Fitting and Refinement
Id
1 (2R5U, 3BH0)
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
The initial fitting was done with the 2R5U and 3BH0 models onto which the E. coli amino sequence had been built. The linker segments that connected t ...
The initial fitting was done with the 2R5U and 3BH0 models onto which the E. coli amino sequence had been built. The linker segments that connected these segments were built by hand.
PHENIX real_space_refine was used to refine the complete model for the B6P5 entity.
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)
8
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
-1
Maximum Defocus (nm)
-3
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
22500
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Preliminary grid screening was performed prior to Krios data collections. All microscope alignments were completed by the New York Structural Biology SEMC team.
EM Software
Task
Software Package
Version
IMAGE ACQUISITION
Leginon
0.0
IMAGE ACQUISITION
Appion
0.0
IMAGE ACQUISITION
Appion
0.0
CTF CORRECTION
Gctf
MODEL FITTING
MOLREP
MODEL FITTING
Coot
SERIES ALIGNMENT
RELION
SERIES ALIGNMENT
Gautomatch
SERIES ALIGNMENT
EMAN2
RECONSTRUCTION
RELION
SERIES ALIGNMENT
TOMO3D
SERIES ALIGNMENT
Dynamo
SERIES ALIGNMENT
EMAN2
RECONSTRUCTION
Dynamo
MODEL REFINEMENT
PHENIX
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
CTF correction was performed before data processing on summed micrographs using Gctf.