☰ Navigation Tabs
Cryo-EM structure of human respiratory complex I matrix arm
Sample Human respiratory complex I matrix arm
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 167761 Reported Resolution (Å) 3.4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON II (4k x 4k) Electron Dose (electrons/Å**2) 1.25
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION EMAN 2.1 IMAGE ACQUISITION AutoEMation 2.0 CTF CORRECTION CTFFIND 3.0 MODEL FITTING Coot 0.8.2 INITIAL EULER ASSIGNMENT RELION 1.4 FINAL EULER ASSIGNMENT RELION 1.4 CLASSIFICATION RELION 1.4 RECONSTRUCTION RELION 1.4 MODEL REFINEMENT PHENIX 1.11.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE