5OAM
Molecular basis of human kinesin-8 function and inhibition
ELECTRON MICROSCOPY
Sample |
---|
13-Protofilament microtuble-bound human Kinesin-8 motor domain neck-linker without nucleotide |
Sample Components |
Tubulin, alpha |
Tublin, beta |
Kinesin-8 motor domain neck-linker |
Specimen Preparation | |
---|---|
Sample Aggregation State | FILAMENT |
Vitrification Instrument | FEI VITROBOT MARK III |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 70395 |
Reported Resolution (Å) | 5.5 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 81 |
Angular Rotation |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 5 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI POLARA 300 |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.3 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | OTHER |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | FEI Polara |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | |
CTF CORRECTION | CTFFIND | 3 |
MODEL FITTING | UCSF Chimera | |
INITIAL EULER ASSIGNMENT | SPIDER | |
FINAL EULER ASSIGNMENT | SPIDER | |
CLASSIFICATION | SPIDER | |
RECONSTRUCTION | FREALIGN | |
MODEL REFINEMENT | Flex-EM | |
MODEL FITTING | Flex-EM |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |